Parent Layer:
Electric
Name: Switch
Display Field: FacilityID
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Copyright Text:
Default Visibility: false
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON
Min Scale: 12000
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 1730700.00639899
YMin: 605560.7862299979
XMax: 1773700.00639899
YMax: 647600.001230001
Spatial Reference: PROJCS["NAD_1983_StatePlane_Arkansas_North_FIPS_0301",GEOGCS["GCS_North_American_1983",DATUM["D_North_American_1983",SPHEROID["GRS_1980",6378137.0,298.257222101]],PRIMEM["Greenwich",0.0],UNIT["Degree",0.0174532925199433]],PROJECTION["Lambert_Conformal_Conic"],PARAMETER["False_Easting",1312333.333333333],PARAMETER["False_Northing",0.0],PARAMETER["Central_Meridian",-92.0],PARAMETER["Standard_Parallel_1",34.93333333333333],PARAMETER["Standard_Parallel_2",36.23333333333333],PARAMETER["Latitude_Of_Origin",34.33333333333334],UNIT["Foot_US",0.3048006096012192]]
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: SubtypeCode
Field 2: null
Field 3: null
Field Delimiter: ,
Default Symbol:
Default Label: null
UniqueValueInfos:
-
Value: 1
Label: Overhead Disconnect
Description:
Symbol:
-
Value: 2
Label: Overhead GOAB
Description:
Symbol:
-
Value: 3
Label: Overhead InLine
Description:
Symbol:
-
Value: 4
Label: Underground Disconnect
Description:
Symbol:
-
Value: 5
Label: Underground GOAB
Description:
Symbol:
-
Value: 6
Label: Open Point
Description:
Symbol:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeNone
Type ID Field: SubtypeCode
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
AncillaryRole
(
type: esriFieldTypeSmallInteger, alias: AncillaryRole
)
-
Enabled
(
type: esriFieldTypeSmallInteger, alias: Enabled
, Coded Values:
[0: False]
, [1: True]
)
-
CreationUser
(
type: esriFieldTypeString, alias: Creation User, length: 20
)
-
DateCreated
(
type: esriFieldTypeDate, alias: Date Created, length: 8
)
-
DateModified
(
type: esriFieldTypeDate, alias: Date Modified, length: 8
)
-
LastUser
(
type: esriFieldTypeString, alias: Last User, length: 20
)
-
SubtypeCode
(
type: esriFieldTypeInteger, alias: Subtype
)
-
FacilityID
(
type: esriFieldTypeString, alias: Bank Facility ID, length: 15
)
-
PhasingCode
(
type: esriFieldTypeInteger, alias: Phasing Code
, Coded Values:
[4: A]
, [2: B]
, [1: C]
, ...4 more...
)
-
OperatingVoltage
(
type: esriFieldTypeInteger, alias: Operating Voltage
, Coded Values:
[230: 13.2 kV Grounded Y]
, [69: 69 kV Delta]
, [762: 7.62 kV Grounded Y]
, ...1 more...
)
-
FeederID
(
type: esriFieldTypeString, alias: Feeder ID, length: 15
)
-
FeederID2
(
type: esriFieldTypeString, alias: Feeder ID - 2, length: 15
)
-
AssemblyCode
(
type: esriFieldTypeString, alias: Assembly Code, length: 10
)
-
Comments
(
type: esriFieldTypeString, alias: Comments, length: 255
)
-
SymbolRotation
(
type: esriFieldTypeDouble, alias: SymbolRotation
)
-
ElectricTraceWeight
(
type: esriFieldTypeInteger, alias: Electric Trace Weight
)
-
FeederInfo
(
type: esriFieldTypeInteger, alias: Feeder Information
)
-
MaxOperatingVoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage
, Coded Values:
[230: 7.62/13.2 kV]
, [380: 39.8/69 kV]
)
-
PosA
(
type: esriFieldTypeInteger, alias: Normal Position - A
, Coded Values:
[1: Normally Closed]
, [0: Normally Open]
, [2: Not Applicable]
)
-
PosB
(
type: esriFieldTypeInteger, alias: Normal Position - B
, Coded Values:
[1: Normally Closed]
, [0: Normally Open]
, [2: Not Applicable]
)
-
PosC
(
type: esriFieldTypeInteger, alias: Normal Position - C
, Coded Values:
[1: Normally Closed]
, [0: Normally Open]
, [2: Not Applicable]
)
-
LabelText
(
type: esriFieldTypeString, alias: Label Text, length: 50
)
-
MaxContinuousCurrent
(
type: esriFieldTypeInteger, alias: Max Continuous Current (Amps)
)
-
Shape
(
type: esriFieldTypeGeometry, alias: Shape
)
-
SPK
(
type: esriFieldTypeInteger, alias: SPK
)
-
LEGACYFEEDERID
(
type: esriFieldTypeString, alias: LEGACYFEEDERID, length: 15
)
-
LEGACYFEEDERINFO
(
type: esriFieldTypeDouble, alias: LEGACYFEEDERINFO
)
-
MOD
(
type: esriFieldTypeString, alias: Motor Operator, length: 5
, Coded Values:
[N: No]
, [Y: Yes]
)
-
MANUFACTURER
(
type: esriFieldTypeString, alias: Manufacturer, length: 50
, Coded Values:
[ABB: ABB]
, [CPR: Cooper Power Systems]
, [GE: General Electric]
, ...7 more...
)
-
ManualOperation
(
type: esriFieldTypeInteger, alias: ManualOperation
, Coded Values:
[0: No]
, [1: Yes]
)
-
InstallDate
(
type: esriFieldTypeDate, alias: Install Date, length: 8
, Coded Values:
[0: No]
, [1: Yes]
)
-
Owner
(
type: esriFieldTypeString, alias: Owner, length: 50
, Coded Values:
[PLWC: Paragould Light Water & Cable]
, [SBC: SouthWestern Bell]
, [ENT: Entergy]
, ...8 more...
)
-
LocationSource
(
type: esriFieldTypeString, alias: Location Source, length: 50
, Coded Values:
[EFA: Estimated from Asbuilts]
, [GPS: GPS]
, [UNK: Unknown]
)
Types:
ID: 2
Name: Overhead GOAB
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MaxContinuousCurrent:
Coded Values:
[600: 600 Amps]
, [900: 900 Amps]
, [1200: 1200 Amps]
-
MANUFACTURER:
Inherited
ID: 3
Name: Overhead InLine
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MaxContinuousCurrent:
Coded Values:
[600: 600 Amps]
, [900: 900 Amps]
, [1200: 1200 Amps]
-
MANUFACTURER:
Inherited
ID: 4
Name: Underground Disconnect
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MaxContinuousCurrent:
Coded Values:
[600: 600 Amps]
, [900: 900 Amps]
, [1200: 1200 Amps]
-
MANUFACTURER:
Inherited
ID: 1
Name: Overhead Disconnect
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MaxContinuousCurrent:
Coded Values:
[600: 600 Amps]
, [900: 900 Amps]
, [1200: 1200 Amps]
-
MANUFACTURER:
Inherited
ID: 5
Name: Underground GOAB
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MaxContinuousCurrent:
Coded Values:
[600: 600 Amps]
, [900: 900 Amps]
, [1200: 1200 Amps]
-
MANUFACTURER:
Inherited
ID: 6
Name: Open Point
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MOD:
Inherited
-
MANUFACTURER:
Inherited
ID: 7
Name: 69kV Disconnect
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MOD:
Inherited
-
MANUFACTURER:
Inherited
-
ManualOperation:
Inherited
-
InstallDate:
Inherited
ID: 8
Name: 69kV GOAB
Domains:
-
Enabled:
Inherited
-
PhasingCode:
Inherited
-
OperatingVoltage:
Inherited
-
MaxOperatingVoltage:
Inherited
-
PosA:
Inherited
-
PosB:
Inherited
-
PosC:
Inherited
-
MOD:
Inherited
-
MANUFACTURER:
Inherited
-
ManualOperation:
Inherited
-
InstallDate:
Inherited
Supported Operations:
Query
Query Attachments
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata